Penetration Testing mailing list archives
[PEN-TEST] PEN TEST Price list
From: Erick Arturo Perez Huemer <eperez () grupotslc com>
Date: Mon, 23 Oct 2000 12:59:00 -0500
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 This might sound silly but we are trying to expand into the PENTEST area, a lillte more deeper..So we reached price issue. Is there any agreed range of price to charge for PENTESTS according to Operating Systems and/or network equipment? Any resource I can read about? Many thanks in advance, Erick A. Perez H. Asesor de Seguridad Informatica Grupo TSLC International S.A. Tel. 223-8327 / Fax 214-9209 email: eperez () grupotslc com - -----Mensaje original----- De: Penetration Testers [mailto:PEN-TEST () SECURITYFOCUS COM]En nombre de McGann, J Enviado el: sábado 21 de octubre de 2000 13:52 Para: PEN-TEST () SECURITYFOCUS COM Asunto: Re: [PEN-TEST] Datacenter Wiring At 10:14 AM 10/21/2000 -0400, Drew Simonis wrote:
Tom Litney wrote:This is a topic that I fear many of us do not take seriously becauseit isnot a "geek" topic - physical security......stonewall(...)My initial question was attempting to solicit an opinion from you, the experts. Disregarding for a minute the hardware on either side of the wire and whether all traffic should be encrypted questions but focusing in on just the physical wire security. You have been approached by one of your clients who is building a datacenter. They are asking your opinion on how they should wire it to provide the best security againstpenetration. Whichmethod would you recommend? Are you a wire walker or a wire hider? And why?I suppose I am a wire hider. I think a nice steel conduit is a heck of a lot better than any other solution Ive heard. And get this twist I've heard about: presurizing the conduit. Charge that pipe up with an inert gas, and if the conduit is broken, for any reason, an alarm is generated. I can't think of a more secure way to protect my cables, can you?
There are some other solutions out there: for example the NSA/DOD approved Cylink Corporation product that puts a fiberoptic wire across the cable pipe. When the pipe is knocked too hard or cut into, the vibration is detected by the FO wire and an alarm sounds. Similar to Drew's pressurization suggestion above. The alarms can be set to ignore vibrations up to a certain level so as not to create too many false alarms. This is a great solution for situations where you are running wire under ground between buildings on a business campus. Peace, Jamie HR Fiderus Strategic Security & Privacy - Security for the Masses || HQ: 919-852-1900 || Cary: 919-654-6837 || TollFree: 866-FIDERUS || || Mobile: 757-535-6605 || Pager: 866-787-1001 - || 8667871001 () skytel com || Fiderus Computer Emergency Hotline # || 1-877-595-8491|| || <jmcgann () fiderus com> || <shadowjcm () mindspring com> || "Energy & persistence conquer all things" -Benjamin Franklin -----BEGIN PGP SIGNATURE----- Version: PGP 6.5.3 iQA/AwUBOfR8WWcbGreM5JWXEQJypwCfTBlvjP7V2dATZVITn4TqOwjj8FIAoKl9 Nb3QS685zHe0oBwWCmabLAK0 =W4EM -----END PGP SIGNATURE-----
Attachment:
Erick Arturo Perez.vcf
Description:
Current thread:
- Re: [PEN-TEST] Datacenter Wiring, (continued)
- Re: [PEN-TEST] Datacenter Wiring Aj Effin ReznoR (Oct 20)
- Re: [PEN-TEST] Datacenter Wiring Darryl Luff (Oct 19)
- Re: [PEN-TEST] Datacenter Wiring JLJ (Oct 19)
- Re: [PEN-TEST] Datacenter Wiring Tom Litney (Oct 20)
- Re: [PEN-TEST] Datacenter Wiring Drew Simonis (Oct 21)
- Re: [PEN-TEST] Datacenter Wiring McGann, J (Oct 21)
- Re: [PEN-TEST] Datacenter Wiring Lady Sharrow (Oct 24)
- Re: [PEN-TEST] Datacenter Wiring Graham Lewis (Oct 25)
- Re: [PEN-TEST] Datacenter Wiring Jose Nazario (Oct 25)
- Re: [PEN-TEST] Datacenter Wiring van der Kooij, Hugo (Oct 25)
- [PEN-TEST] PEN TEST Price list Erick Arturo Perez Huemer (Oct 24)
